Resource Hierarchy

Redfish Server

  • Manager
    • Manager Network Interface
  • Chassis
    • Compute System
      • System Ethernet Interface
      • Processor
      • Drives
      • Memory
    • NetworkAdapter
    • Power Supply
    • Fan
    • Temperature Sensors
    • PCIe Device
    • Assemblies
  • Firmware
  • Software

Supported Metrics

Click here to view the supported metrics
Native TypeMetric NameDisplay NameUnitsMetric CategoryApplication VersionDescription
Redfish Serverredfish_server_APIStatisticsRedfish Server API StatisticsUsage10.0.0Returns number of API calls made on each native type for each pole.
Managerredfish_manager_HealthStatusRedfish Manager Health StatusAvailability10.0.0Returns the health status of the Manager. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_manager_StateRedfish Manager StateAvailability10.0.0Returns the availability state of the Manager. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
Chassisredfish_chassis_HealthStatusRedfish Chassis Health StatusAvailability10.0.0Returns the health status of the Chassis. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_chassis_StateRedfish Chassis StateAvailability10.0.0Returns the availability state of the Chassis. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
redfish_chassis_powercontrol_PowerConsumedWattsRedfish Chassis PowerControl Power Consumed WattsWPower10.0.0Redfish Chassis PowerControl Power Consumed Watts.
Compute Systemredfish_computeSystem_HealthStatusRedfish Compute System Health StatusAvailability10.0.0Returns the health status of the Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_computeSystem_memory_HealthStatusRedfish Compute System Memory Health StatusAvailability10.0.0Returns the health status of the Memory of Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_computeSystem_StateRedfish Compute System StateAvailability10.0.0Returns the availability state of the Compute System. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCed(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
redfish_computeSystem_HealthRollupStatusRedfish Compute System Health Rollup StatusAvailability10.0.0Returns the healthRollup status of the Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_computeSystem_PowerStateRedfish Compute System Power StateWPower10.0.0Returns the Power Status of the Compute System, Possible states are OFF(0), ON(1), POWERINGOFF(2), POWERINGON(3).
Compute Systemredfish_computeSystem_BootProgress_LastStateRedfish Compute System BootProgress StateAvailability10.0.0Redfish Compute System BootProgress State, Possible states are NONE(0), PRIMARYPROCESSORINITIALIZATIONSTARTED(1), BUSINITIALIZATIONSTARTED(2), MEMORYINITIALIZATIONSTARTED(3), SECONDARYPROCESSORINITIALIZATIONSTARTED(4), PCIRESOURCECONFIGSTARTED(5), SYSTEMHARDWAREINITIALIZATIONCOMPLETE(6), SETUPENTERED(7), OSBOOTSTARTED(8), OSRUNNING(9), OSSERVICESREADY(10), OSSERVICESOFFLINE(11), OSHALTING(12), OSHALTED(13)
Processorredfish_processor_HealthStatusRedfish Processor Health StatusAvailability10.0.0Returns the health status of the Compute System Processor. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_processor_StateRedfish Processor StateAvailability10.0.0Returns the availability state of the Compute System Processor. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
Driveredfish_drive_HealthStatusRedfish Drive Health StatusAvailability10.0.0Returns the health status of the Drive. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_drive_StateRedfish Drive StateAvailability10.0.0Returns the availability state of the Drive. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
Memoryredfish_memory_HealthStatusRedfish Memory Health StatusAvailability10.0.0Returns the health status of the Memory Components. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_memory_StateRedfish Memory StateAvailability10.0.0Returns the availability state of the Memory Components. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
Network Adapterredfish_networkAdapter_AggregateBandwidthRedfish Network Adapter Aggregate BandwidthGbpsPerformance10.0.0Redfish Network Adapter Aggregate Bandwidth
Power Supplyredfish_powerSupply_HealthStatusRedfish Power Supply Health StatusAvailability10.0.0Returns the health status of the Power Supply. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_powerSupply_StateRedfish Power Supply StateAvailability10.0.0Returns the availability state of the Power Supply. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
Fanredfish_fan_HealthStatusRedfish Fan Health StatusAvailability10.0.0Returns the health status of the Fan. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_fan_StateRedfish Fan StateAvailability10.0.0Returns the availability state of the Fan. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
redfish_fan_ReadingRedfish Fan ReadingUsage10.0.0Returns the reading value of the Fan.
Temperature Sensorsredfish_temperature_ReadingRedfish Temperature ReadingCelsiusThermal10.0.0Returns the reading value (in Celsius) of the Temperature.
PCIe Deviceredfish_pciedevice_HealthStatusRedfish PCIe Device Health StatusAvailability10.0.0Returns the health status of the PCIe Device. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_pciedevice_HealthRollupStatusRedfish PCIe Device Health Rollup StatusAvailability10.0.0Returns the healthRollup status of the Assembly. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_pciedevice_StateRedfish PCIe Device StateAvailability10.0.0Returns the availability state of the PCIe Device. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
Assembliesredfish_assembly_HealthRollupStatusRedfish Assembly Health Rollup StatusAvailability10.0.0Returns the healthRollup status of the Assembly. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_assembly_HealthStatusRedfish Assembly Health StatusAvailability10.0.0Returns the health status of the Assembly. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_assembly_StateRedfish Assembly StateAvailability10.0.0Returns the availability state of the Assemblies. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).